SIGNAL State: INTEGER RANGE 0 TO 3

PROCESS(CLK)

BEGIN

IF CLK EVENT AND CLK=’1′ THEN

IF State<3 THEN

State<=State+1;

ELSE

State<=0;

PROCESS(State)

BEGIN

CASE State

WHEN 0=>rgy<=”001100″;

WHEN 1=>rgy<=”010100″;

WHEN 2=>rgy<=”100001″;

WHEN 3=>rgy<=”100010″;